Immunoturbidimetry


Ref Description Pack
1360050 a-1-Antitrypsin 1×20 ml
 a-1-antitrypsin immunoturbidimetric determination. Liquid monoreagent, end point in 5 minutes. Sample Report / R1: 1/125. Linearity: 600 mg / dl. Reading at 340 nm. Without pre-sampling.
1370050-28 a-1-Acid glycoprotein 1×28 ml
Immunoturbidimetric method for the determination of acid a-1-glycoprotein. Liquid monoreagent, end point in 10 minutes. Sample report/R1:1/83.3. Linearity: 250 mg/dl. Absorption 340 nm. No predilution of the sample.
1390050 a-2-Macroglobulin 1×20 ml
Immunoturbidimetric method for the determination of a-2-macroglobulin. Liquid end point in 5 minutes. Monoreagent. Sample report/R1:1/41.7. Linearity: 600 mg/dl. Absorption 340 nm. No predilution of the sample.

 

DZ0020H a-Fetoproteina 1×48 + 1×15 ml
Immunoturbidimetric determination of a-fetoprotein. Bi-reactive liquid, end point in 10 minutes. Sample report/R1/R2:1/28.57/7.14. Linearity: 253.8 ng/ml. Read at 570 nm. No predilution of the sample.

 

1400050 b-2-Microglobulin 1×40 + 1×10 ml
Immunoturbidimetric determination of b-2-microglobulin in serum, plasma and urine. Bi-reactive, end point in 5 minutes. Sample report /R1/R2:1/90 (18 urine)/10 (2 urine). Linearity: 18 mg/l serum and 3 mg/l for urine. Absorption 540 nm. Standard kit. No predilution of the sample.

 

1410050-28 Antithrombin III 1×28 ml
Immunoturbidimetric method for determination of Antithrombin III. Liquid monoreactive, end point in 20 seconds. Sample report/R1:1/5. Linearity: 72 mg/dl. Absorption 340 nm. No predilution of the sample.

 

1420050 Apolipoprotein A-1 50+5 ml
Immunoturbidimetric method for determination of apolipoprotein A-1. Liquid bi-reagents, end point in 10 minutes. Sample report/R1/R2 1/90/8. Linearity: 300 mg/dl. Absorption 340 nm. No predilution of the sample.
1430050 Apolipoprotein B 50+5 ml
Immunoturbidimetric method for determination of apolipoprotein B. Liquid bi-reagents, end point in 10 minutes. Sample report 1/R1/R2/22.5/2. Linearity: 330 mg/dl. Absorption 340 nm. No predilution of the sample.
1440050 Haptoglobin 1×20 ml
Immunoturbidimetric method for determination of haptoglobin. Liquid monoreagent end point in 5 minutes. Sample report/R1:1/50. Linearity: 530 mg/dl. Absorption 340 nm. No predilution of the sample.

 

1640050-50 ASO 1×45 + 1×5 ml
Immunoturbidimetric method for the detection of antibodies to streptolysin O. Bi-reactive, end points in 10 minutes. Sample report/R1/R2:1/120/13.3. Linearity: 750 IU/ml. Absorption 500 nm. Complete calibrator Kit.
1021024 C1 ESTERASE INHIBITOR 1×24 ml
Immunoturbidimetric method for determination of C1 esterase inhibitor.

 

1490025 C3 1×25 ml
Immunoturbidimetric method for the determination of the C3. Liquid monoreagent end point in 5 minutes. Sample report/R1:1/50. Linearity: 300 mg/dl. Absorption 340 nm. No predilution of the sample.

 

1500025 C4 1×25 ml
Immunoturbidimetric method for the determination of C4. Liquid monoreagent end point in 5 minutes. Sample report/R1:1/50. Linearity: 300 mg/dl. Absorption 340 nm. No predilution of the sample.

 

1450050-40 Chains k 1×40 ml
Immunoturbidimetric method for determination of Kappa light chain in serum and urine. Liquid end point in 10 minutes. monoreagent. Sample rate/R1:1/25. Linearity: 20.4 mg/dl. Absorption 340 nm. No predilution of the sample.

 

1460050-40 Chains l 1×40 ml
Immunoturbidimetric method for determining lambda light chain in serum and urine. Liquid monoreagent end point in 10 minutes . Sample report/R1:1/25. Linearity: 22.0 mg/dl. Absorption 340 nm. No predilution of the sample.

 

1480050 Ceruloplasmin 1×20 ml
Immunoturbidimetric method for determination of ceruloplasmin. Liquid monoreagent, end point in 20 seconds. Sample report/R1:1/50. Linearity: 170 mg/dl. Absorption 340 nm. No predilution of the sample.

 

1510050 Ferritin 1×40 + 1×10 ml
Immunoturbidimetric method for determination of serum Ferritin. Liquid bireagent end point in 10 minutes . Sample report/R1/R2:1/8/3. Linearity: 300 ng/dl. Absorption 600 nm. No predilution of the sample. Absorption calibrator Kit.

 

1520050 Fibrinogen 2×20 ml
Immunoturbidimetric method for the determination of plasma Fibrinogen treated with sodium citrate. Liquid monoreagent end point in 5 minutes. Sample report/R1:1/125. Linearity: 800 mg/dl. Absorption 340 nm. No predilution of the sample.

 

1530025 IgA 1×25 ml
Immunoturbidimetric method for determination of immunoglobulins of type IgA in serum and plasma. Liquid  Monoreagent end point in 5 minutes. Sample report/R1:1/50. Linearity: 525 mg/dl. Absorption 340 nm. No predilution of the sample.

 

1540050-28 IgE 1×25 + 1×4 ml
  Immunoturbidimetric method for determination of immunoglobulins IgE. Liquid bi-reagents, end point in 5 minutes. Sample report/R1/R2:1/8.2/3.0. Linearity: 1000 IU/ml. Absorption 600 nm. No predilution of the sample.

 

1550025 IgG 1×25 ml
Immunoturbidimetric method for the determination of IgG in serum. Liquid monoreagent end point in 10 minutes. Sample report/R1:1/166.67. Linearity: 2367 mg/dl. Absorption 340 nm. No predilution of the sample.
1560025 IgM 1×25 ml
Immunoturbidimetric method for determination of serum IgM immunoglobulins. Liquid monoreagent end point in 10 minutes. Sample report/R1:1/33.3. Linearity: 378 mg/dl. Absorption 340 nm. No predilution of the sample.
1570050 Lipoprotein A 2×20 ml
Determination immunoturbidimetrica, lipoprotein molecule very similar to low density lipoprotein (LDL) and head of thrombosis, inflammation and formation of foam cells. End points in 10 minutes. In serum and plasma. Sample report/R1/R2:1/45/12. Linearity: 800 mg/l. Absorption 600 nm. No predilution of the sample.

 

1580055-20 Microalbuminuria 1×20 + 1×4 ml
Immunoturbidimetric method for determination of microalbumin in urine samples. Liquid bi-reagents, end point in 10 minutes. Sample report/R1/R2:1/156.25/31.75. Linearity: 400 mg/l. Absorption 405 nm. No predilution of the sample. Complete calibrator Kit.

 

1630050-50 PCR 1×45 + 1×5 ml
Immunoturbidimetric method for determination of C-reactive protein (CRP) in serum or plasma. Liquid bi-reagents end point in 10 minutes. Sample report/R1/R2:1/90/10. Linearity: 100 mg/dl. Absorption 500 nm. No predilution of the sample. Complete calibrator Kit.
1600050 Prealbumin 2×20 ml
Immunoturbidimetric method for determination of prealbumin in serum and plasma. Liquid monoreagent end point in 5 minutes. Sample report/R1:1/25. Linearity: 134 mg/dl. Absorption 340 nm. No predilution of the sample.

 

1620050-50 RT 1×45 + 1×5 ml
Immunoturbidimetric method for determination of rheumatoid factor in serum and human plasma. Liquid bi-reagents end points in 10 minutes. Sample report/R1/R2:1/90/10. Linearity: 120 IU/ml. Absorption 550 nm. No predilution of the sample. Calibrator Kit.

 

1610025 Transferrin 1×25 ml
Immunoturbidimetric method for the determination of human serum and plasma transferrin. Liquid monoreagent end point in 5 minutes. Sample report/R1:1/83.3. Linearity: 610 IU/ml. Absorption 340 nm. No predilution of the sample.